our ServiceAll columns are made from ultra-high purity silica, minimizing metallic impurities, enhancing chemical inertness, and improving reproducibility—especially for polar compounds.
ChromXcel™ C18

ChromXcel™ C18

  • Pore Size (Å) : 100 Å
  • Surface area (m²/g) : 350 m²/g
  • Carbon % : 18%
  • pH Stability : 2 to 8
  • Particle Sizes (µm) : 2,3,3.5,4,5,10
  • End Capped : Yes
  • USP Code : L-1
ChromXcel™ C18-AQ

ChromXcel™ C18-AQ

  • Pore Size (Å) : 100 Å
  • Surface area (m²/g) : 300 m²/g
  • Carbon % : 12%
  • pH Stability : 2 to 8
  • Particle Sizes (µm) : 5
  • End Capped : Yes
  • USP Code : L-1
ChromXcel™ C8

ChromXcel™ C8

  • Pore Size (Å) : 100 Å
  • Surface area (m²/g) : 340 m²/g
  • Carbon % : 12%
  • pH Stability : 2 to 8
  • Particle Sizes (µm) : 2,3,3.5,4,5
  • End Capped : Yes
  • USP Code : L-7
ChromXcel™ NH2

ChromXcel™ NH2

  • Pore Size (Å) : 100 Å
  • Surface area (m²/g) : 350 m²/g
  • Carbon % : 4%
  • pH Stability : 2 to 8
  • Particle Sizes (µm) : 5
  • End Capped : No
  • USP Code : L-8
ChromXcel™ CN

ChromXcel™ CN

  • Pore Size (Å) : 100 Å
  • Surface area (m²/g) : 350 m²/g
  • Carbon % : 6.5%
  • pH Stability : 2 to 8
  • Particle Sizes (µm) : 5
  • End Capped : No
  • USP Code : L-10
ChromXcel™ Silica

ChromXcel™ Silica

  • Pore Size (Å) : 100 Å
  • Surface area (m²/g) : 350 m²/g
  • Carbon % : 0
  • pH Stability : 2 to 8
  • Particle Sizes (µm) : 5
  • End Capped : No
  • USP Code : L-3
ChromXcel™ Phenyl

ChromXcel™ Phenyl

  • Pore Size (Å) : 100 Å
  • Surface area (m²/g) : 350 m²/g
  • Carbon % :11%
  • pH Stability : 2 to 8
  • Particle Sizes (µm) : 5
  • End Capped : Yes
  • USP Code : L-11
ChromXcel™ PFP

ChromXcel™ PFP

  • Pore Size (Å) : 120 Å
  • Surface area (m²/g) : 320 m²/g
  • Carbon % :12%
  • pH Stability : 2 to 8
  • Particle Sizes (µm) : 3,5
  • End Capped : Yes
  • USP Code : L-43

Special Product Highlight

ChromXcel™ Ghost Buster Column

A unique solution for removing “ghost peaks” from HPLC runs.

service-details__image__item

Key Benefits

Size: 50 mm × 4.6 mm ID

  • Cleans up the baseline and improves accuracy
  • Protects the main analytical column from contaminants
  • Extends column lifespan
  • Easy to integrate and highly cost-effective

Applications

  • Pharmaceutical Drug Analysis
  • Polar and Hydrophilic Compound Separation
  • Environmental Sample Testing
  • Food & Beverage Quality Assurance
  • Clinical & Biological Fluids
  • Herbal and Natural Products

Download Our Brochure

Get detailed information about our services, features and more.

labiox